Measuring and Improving Cardiac Arrest Resuscitation in the Emergency Department (MICARE)
1. Setting
Type of Setting: Academic
Annual Census Volume: 65,000
Area of Focus: Clinical care – quality improvement of cardiac arrest management in the ED
Description of Local Context:
St. Michael’s Hospital is a tertiary care centre and regional centre for stroke, STEMI, and trauma programs. We serve a significant inner-city population, with approximately 25% of our ED visits from marginalized individuals who are unhoused.
2. Description of the Problem
Cardiac arrest management is a core component of emergency medicine. Although the American Heart Association recommends routine quality improvement processes as an essential part of resuscitation care, few emergency departments (EDs) consistently collect, analyze, and act on CPR quality metrics.
As a result, discrepancies often exist between delivered CPR and best-practice guidelines. In our ED, CPR quality data were available for only 48.7% of non-traumatic cardiac arrest cases, limiting our ability to review performance, plan targeted quality improvement (QI) initiatives, and improve resuscitation quality.
3. Stakeholders
ED physicians, nurses, nurse educators, simulation specialists, clinical assistants, clerical staff, QI specialists, the in-hospital cardiac arrest committee, and EMS. Engagement included QI huddles, simulation sessions, education rounds, and iterative feedback.
4. Costs and Funding Sources
Costs included the purchase of EMS-to-ED pad adapters and minor hardware modifications. The project was supported by internal departmental QI resources.
5. Methods Used
QI methods included stakeholder analysis, Ishikawa diagramming, process mapping, and iterative Plan-Do-Study-Act (PDSA) cycles.
Interventions included:
Introduction of EMS-to-ED adapters
Simulation for workflow testing and education
CPR feedback training
Post-event data debriefing
P-charts and X-charts were used to evaluate change.
6. Results/Data
The main outcome measure was the proportion of cases with CPR data available, with a target of 80%.
Key results included:
CPR data capture: Improved from 48.7% to 89.1%, meeting special-cause thresholds.
CPR in-target for rate and depth: Improved from 1.8% to 20.4%.
Compression fraction: Improved from 82.2% to 86.9%.
Pauses under 10 seconds: Did not show special-cause variation.
7. Barriers/Challenges
Challenges included initial staff concerns about individual performance review, a misplaced adapter, differences in EMS pad compatibility, and limited EHR timestamps.
These challenges were addressed through culture-building, simulation, education, and securing adapters to defibrillator cables.
8. Team Engagement
Daily QI huddles, simulation, champions among nurses and physicians, and non-punitive aggregate data review helped create trust and sustain engagement.
9. Sustainable Successes
CPR data capture now remains consistently above 80%, establishing a strong foundation for further quality improvement initiatives.
This infrastructure has supported the integration of a dedicated CPR coach role, expanded simulation training, skills-day education, and routine post-event debriefing.
It has also enabled more targeted projects examining CPR quality during EMS-to-ED transitions and analyzing CPR pause times, further advancing our ability to optimize resuscitation performance.
10. Impact on Morale
This project has improved team performance during arrests, provided frontline staff with feedback metrics, and established a foundation for further resuscitation quality improvement projects.
Furthermore, the integration of a CPR coach role has allowed greater autonomy for nursing staff and enabled them to take a more vocal role during clinical cases.
11. General Reflection
Simulation-supported PDSA cycles enabled smooth adoption of new workflows. Strong interprofessional collaboration was foundational to the project's success.
This model is scalable to other EDs with access to compatible defibrillator systems.
12. Bottom Line
A structured QI initiative integrating simulation, education, technology optimization, and data debriefing improved ED CPR data capture from 48.7% to 89.1% and established a foundation for future CPR quality improvement.